Insight

Mining & Industrial

Assay QAQC Explained: How Standards, Blanks and Duplicates Protect Your Drill Results

What assay QAQC checks, how standards, blanks and duplicates each catch a different problem, typical insertion rates, and what to review on every batch.

ZA Technologies

November 18, 2026

Abstract web of fine copper lines on a dark background.

Mining & Industrial

Source

View the original source

Assay QAQC, short for quality assurance and quality control, is how an exploration team proves that the numbers coming back from the laboratory can be trusted. Every drill result that reaches a press release, a technical report or a buyer's data room rests on it. When QAQC is done well, nobody notices. When it is skipped or checked too late, the problem usually surfaces at the worst possible moment: during a resource estimate, a financing or a due diligence review.

Why assay QAQC matters

A laboratory can return a clean looking certificate that is quietly wrong. A standard can drift, a sample can be contaminated during crushing, two bags can be swapped, or a high grade sample can exceed the method's upper limit without being rerun. None of these show up by reading the assay values alone. Control samples are inserted into the sample stream precisely so that these failures become visible.

Public reporting raises the stakes. Canadian disclosure rules for mineral projects expect the data quality behind reported results to be explained, and the Qualified Person signing a technical report needs evidence that the data was checked, not an assurance that it probably was.

The three control samples and what each one catches

Certified reference materials (standards)

A standard is material with a known, certified grade. If the laboratory reports a standard well away from its certified value, the accuracy of the whole batch around it is in question. Many programs treat a result outside two standard deviations as a warning and outside three as a failure that triggers investigation or reassay of the surrounding samples.

Blanks

A blank contains effectively none of the target element. A blank that comes back with a meaningful grade points to contamination, often carried over from a high grade sample during preparation, or to a sample mix up. Coarse blanks, inserted before crushing, test the preparation stage as well as the analysis.

Duplicates

Duplicates measure precision: how closely the same material repeats. Field duplicates test the entire sampling process, coarse reject duplicates test preparation, and pulp duplicates test the laboratory's analytical precision. Comparing the three shows where variability enters the process.

Each control type tests a different failure. A program with plenty of standards but no blanks can miss contamination entirely, so one does not replace another.

How many control samples to insert

There is no single industry standard insertion rate. A common baseline is one standard, one blank and one duplicate for roughly every 20 samples, which works out to about 10 to 15 percent of the sample stream. Industry reviews of exploration practice often cite around 20 percent in total, at roughly 4 to 6 percent for each control type. Early stage programs tend to sit lower, resource drilling higher, and nuggety or coarse gold deposits may need considerably more duplicates and blanks. Whatever the rate, control samples should be inserted blind, so the laboratory cannot tell them from routine samples.

What to check on every batch

  • Insertion compliance. Were the planned standards, blanks and duplicates actually inserted at the agreed rate and in the right positions?
  • Standard performance. Does each standard fall within its acceptable limits, and is there any drift across consecutive batches?
  • Blank values. Does any blank return a grade that suggests contamination or a swap?
  • Duplicate precision. Do duplicate pairs agree within the tolerance expected for that duplicate type and grade range?
  • Over limit samples. Has every sample above the method's upper detection limit been sent for reassay by an appropriate method?
  • A recorded outcome. Is every failure listed with its reason, and is the decision taken (reassay, investigate or accept with justification) written down?

Where assay QAQC usually goes wrong

The most common failure is not technical. It is timing. Assay files arrive from the lab, get pasted into a spreadsheet, and are checked by hand when someone has time. Checks happen weeks later, in a different format each time, and the evidence of what was reviewed lives in someone's inbox. A failed standard found on site the week it arrives is a conversation with the laboratory. The same failure found months later by a buyer is a valuation problem.

Checking every batch by system

QAQC by ZA Technologies validates each assay batch as it arrives. It checks every sample, verifies insertion compliance, evaluates standards, blanks and duplicates, flags over limit samples, and lists every failure with the reason it was flagged. Each run produces a clear verdict and a report your team keeps, so the evidence trail exists before anyone asks for it. Your Qualified Person still interprets the geology and signs the disclosure; the system makes sure their time goes to judgement instead of file cleaning.

Qualified exploration teams can run QAQC free for one month on their own assay data, in a private workspace, with reports they keep either way.

For mining exploration teams

Run QAQC free for one month on your own assay data.

A private workspace for your company, your real assay batches, and reports you keep either way. No card and no commitment. After the beta, the subscription is scoped with you and confirmed in writing.